Staff
HomeNewsSebastian Jacobs /  The Cleveland Hose Load

QuickLay Fire Attack News & Articles

Hose, equipment and the fire response industry

The Cleveland Hose Load

Posted by Sebastian Jacobs
Sebastian Jacobs
Keen Australian based fire fighter
User is currently offline
on Tuesday, 27 August 2013
in Water on the Fire

One method - many names!

It has lots of names and just as many origins- the act of wrapping the first bite of hose back on itself (about 1.8m) and continuing to wrap until there's about 1m left.

This is commonly called the Cleveland Hose Load, the Round About Hose Load, the Garden Lay etc etc - we're not certain of it's origin however the Cleveland State Forest fire fighters were said to employ the concept for deploying hose at wild fires (great idea!!!).

What we are certain about is it's great! Especially when used in conjunction with an initial flaked hose, as it's possible to stretch and coil 2 lengths of hose just as quickly as the ground between the water supply and the fire can be covered.

We are often asked why we don't just have two packs holding coiled hose and not bother with the flaked hose pack, which on face-value- having two hoses rapidly deployed in a tight area sounds like a good thing- but it's not, or at least we don't think so.

For all its amazing benefits the Cleveland Hose Load has a few short comings which are inherent to the nature of lay-flat hose.

  1. Hose stored in the Cleveland Hose Load should not be run out from it's coiled position until it's full of water- this is because it will twist as it unravels from the coil and when the water is introduced the nozzle/branch will untwist. For this reason the line cannot be advanced until it's full of water.
  2. When deployed in the right position (near to the fire) the Cleveland Hose Load is easily advanced from its tight coil into the burning environment. However if two Cleveland Hose Loads are deployed together too far away, then the ease-of-advancement is burnt up in the distance between the supply and the fire. Then on entry, we are back to the original problem of lots of heavy hose outside.

To solve these problems we have developed a second pack (Lay Pack) designed to cover the distance between the water supply and the coiled hose.

When the two packs are used together, the distance between the fire and supply can be covered in either a forward or reverse direction (depending on the job) and hose deployed into a coil from the Attack Pack can be advanced into the burning environment.

For scenarios where there's a lay flat hose already positioned for each hydrant we have developed the Compack - it too stores and deploys the Cleveland Hose Load in one movement and is stored in more of a square shaped pack so it can fit in traditional fire hose cabinets.

The benefits of a coiled hose deployed in a lift lobby or stairwell environment far outweigh the current hose-rack flaked hoses as it can be deployed almost instantly and does not need to be stretched up and back in limited spaces.

  1. In this scenario the Attack Packs holding the coil are deployed near to the fire.

  2. Where the Lay Packs have been stretched up or down the stairs, to or from the water supply.

 

 

0 votes

Comments

No comments made yet. Be the first to submit a comment

Leave your comment

Guest
Guest Tuesday, 12 December 2017
Copyright © 2017. Quicklay Fire Attack - Highrise Kits | Remote Access Packs | Fire Hose Bags. Designed by quicklayfireattack.com