Water on the Fire

"Water on the Fire" is about core skills! It's about back-to-basics and doing it well. So much innovation and so many new techniques have evolved we want to create awareness around the foundation of what it means to be a great fire fighter!

Why dont you use straps?

Posted by Sebastian Jacobs
Sebastian Jacobs
Keen Australian based fire fighter
User is currently offline
on Thursday, 29 August 2013
in Water on the Fire · 0 Comments

"Why don't you just use straps?"

Is a question we sometimes get!

The best way to appreciate the bigger picture is to consider the value of a firefighter's helmet. I personally have worn my helmet for 12 years and for the first time only 3 months ago did it actually do its job and protect my head from a falling garage door while operating in an underground car park fire- absolutely saving my life.

For 11 or so years prior to this nothing fell on my head but the one time it did the total cost of the few helmets I've had paid for themselves with my life.

So yes, you can just use a set of straps and generally they will hold the hose...

But what if?

  • You trip and drop the load and it looses its form?
  • You want to throw the whole load across a gap to a boat or building and the exposed hose gets snagged?
  • You want to only deploy half the hose, not the whole hose, causing the remaining half to loose its form?
  • You want to be able to open the the locker on the pumper and know the load will definitely be good-to-go?
  • You need to deploy hose in poor visibility?
  • You arrive at a big job with people you've not worked with before and want to be tasked based on the pack you have - not a long discussion?
  • You want to feed the neatly packed hose through a gap or under/over a fence?
  • You're working with a crew you don't know and they have a different way of strapping the hose?
  • You just want to become really efficient with a dedicated piece equipment that's been tried and tested and designed for one task...

In these very possible scenarios straps just don't cut it.

In my last article I discussed the The Cleveland Hose Load and specifically why it's great as well as its inherent shortcomings-

If you add the use of straps there's a whole lot more to consider with the Cleveland Hose Load, most importantly:

  • The thumb knot or Overhand Knot.

The Attack Pack deliberately isolates the two hose ends from the main body of the hose, this prevents the catastrophic failure caused when one hose end pops under one or more coils forming a simple but show-stopping thumb knot.

Hits: 2402
0 votes
Posted by Sebastian Jacobs
Sebastian Jacobs
Keen Australian based fire fighter
User is currently offline
on Tuesday, 27 August 2013
in Water on the Fire · 0 Comments

One method - many names!

It has lots of names and just as many origins- the act of wrapping the first bite of hose back on itself (about 1.8m) and continuing to wrap until there's about 1m left.

This is commonly called the Cleveland Hose Load, the Round About Hose Load, the Garden Lay etc etc - we're not certain of it's origin however the Cleveland State Forest fire fighters were said to employ the concept for deploying hose at wild fires (great idea!!!).

What we are certain about is it's great! Especially when used in conjunction with an initial flaked hose, as it's possible to stretch and coil 2 lengths of hose just as quickly as the ground between the water supply and the fire can be covered.

We are often asked why we don't just have two packs holding coiled hose and not bother with the flaked hose pack, which on face-value- having two hoses rapidly deployed in a tight area sounds like a good thing- but it's not, or at least we don't think so.

For all its amazing benefits the Cleveland Hose Load has a few short comings which are inherent to the nature of lay-flat hose.

  1. Hose stored in the Cleveland Hose Load should not be run out from it's coiled position until it's full of water- this is because it will twist as it unravels from the coil and when the water is introduced the nozzle/branch will untwist. For this reason the line cannot be advanced until it's full of water.
  2. When deployed in the right position (near to the fire) the Cleveland Hose Load is easily advanced from its tight coil into the burning environment. However if two Cleveland Hose Loads are deployed together too far away, then the ease-of-advancement is burnt up in the distance between the supply and the fire. Then on entry, we are back to the original problem of lots of heavy hose outside.

To solve these problems we have developed a second pack (Lay Pack) designed to cover the distance between the water supply and the coiled hose.

When the two packs are used together, the distance between the fire and supply can be covered in either a forward or reverse direction (depending on the job) and hose deployed into a coil from the Attack Pack can be advanced into the burning environment.

For scenarios where there's a lay flat hose already positioned for each hydrant we have developed the Compack - it too stores and deploys the Cleveland Hose Load in one movement and is stored in more of a square shaped pack so it can fit in traditional fire hose cabinets.

The benefits of a coiled hose deployed in a lift lobby or stairwell environment far outweigh the current hose-rack flaked hoses as it can be deployed almost instantly and does not need to be stretched up and back in limited spaces.

  1. In this scenario the Attack Packs holding the coil are deployed near to the fire.

  2. Where the Lay Packs have been stretched up or down the stairs, to or from the water supply.

 

 

Hits: 5270
0 votes
Posted by Sebastian Jacobs
Sebastian Jacobs
Keen Australian based fire fighter
User is currently offline
on Saturday, 17 August 2013
in Water on the Fire · 0 Comments

Don't worry! We're big fans of the work that has been pioneered by a few very keen and extremely competent individuals who may all speak different languages yet agree that there's a better way than "Big Fire = Big Water".

But... What is the point of learning all these fantastic techniques- if you cannot get water on the fire quickly and reliably due to hose tangles, kinks and catch points?

'We have procedures' is something we hear - however when quizzed further, more often than not the procedures are "get hose out" - not how to lay hose. What if the usual crew isn't working together? What if a multilingual crew is thrust together on an oil-rig or cruise ship?

Our aim isn't to change anything- we simply hope to add value with some purpose built packs.

For example the Lay Pack is blue because it stretches water between the water supply and the Attack Pack. The Attack Pack is red because it contains the hose that will attack the fire.

First and second arriving fire fighters now know without any words spoken that 60m or 200ft of hose is ready to be laid and who has what role based on the pack they're carrying.

After consultation with fire fighters in Australia, the Mid East, Europe and the USA we have come to the conclusion that when laying hose what's important is:

  • The distance is covered once by the fire fighters - maximum twice
  • Hose is laid only once - not deployed and then bundled up and redeployed
  • Enough hose is deployed - ready to advance into the fire without friction or catch-points causing delays

 